Which rating matters on your electric bill?
The variable-speed Rheem rates 19 SEER2 against 16.5 for the two-stage Lennox. For the same seasonal cooling load, the Rheem rating implies about 13% less electricity. For a hot afternoon, look at EER2 instead. The Lennox earns 13.4 against 12 for the Rheem, equivalent to about 0.90 versus 1.00 kW per ton of cooling at the EER2 test point.
Check the load before comparing those percentages
The Lennox match delivers 36,000 Btu/h of rated cooling, while the Rheem delivers 34,200. Ask the contractor to check each system’s output at your local summer design conditions. If both fit, use your cooling hours and rate to value the seasonal savings. For a house that often feels damp, also request the low-stage or minimum cooling output and the proposed indoor airflow.
Specifications side by side
Figures apply to the equipment combinations shown. N/A marks a field that is missing or does not apply. These ratings come from the EPA’s final central AC archive. Check the exact match and availability with your installer.
| Specification | Lennox ML17KC2-036-230A** | Rheem RA19AY36AJVC |
|---|---|---|
| System type | Split central air conditioner | Split central air conditioner |
| Outdoor / packaged model | ML17KC2-036-230A** | RA19AY36AJVC |
| Indoor model | CBK45UHET-048-230-** | RHMVY3621MEACA |
| AHRI reference | 216049009 | 215737347 |
| EPA product ID | 3802925 | 3666247 |
| Compressor staging | Two-stage | Variable-speed |
| Refrigerant | R-454B | R-454B |
| Cooling capacity | 36,000 Btu/h | 34,200 Btu/h |
| SEER2 | 16.5 | 19 |
| EER2 | 13.4 | 12 |