When the seasonal ratings tie
The Goodman uses a single-stage compressor and the Rheem has two stages. Their seasonal ratings are identical at 15.2 SEER2 and 7.8 HSPF2. If the Rheem bid costs more, give the extra stage its own question. How much cooling can it deliver on low stage, and how often is the house likely to need that amount? A longer low-stage run may be useful in a house that feels damp between short cycles.
There is a gap in the cold-weather comparison
At 17°F the Rheem delivers 30,000 Btu/h of heat against 28,000 for the Goodman. At 5°F the Goodman record gives 21,000 Btu/h at a COP of 2.0. The Rheem record has no values for that point. Ask for Rheem’s extended performance table for the quoted indoor and outdoor units before comparing backup needs. Extrapolating the 17°F lead would turn a missing measurement into a guess.
Specifications side by side
Figures apply to the equipment combinations shown. N/A marks a field that is missing or does not apply.
| Specification | Goodman GLZS5BA4810A* | Rheem RP15AY48AJ2N |
|---|---|---|
| System type | Split heat pump | Split heat pump |
| Outdoor / packaged model | GLZS5BA4810A* | RP15AY48AJ2N |
| Indoor model | AMST48CU1300A* | RH2TY4821STANN |
| AHRI reference | 215381164 | 215415452 |
| EPA product ID | 3984045 | 3624777 |
| Compressor staging | Single-stage | Two-stage |
| Refrigerant | R-32 | R-454B |
| Cooling capacity | 45,500 Btu/h | 45,500 Btu/h |
| SEER2 | 15.2 | 15.2 |
| EER2 | 12.5 | 11.7 |
| HSPF2 | 7.8 | 7.8 |
| Heat at 47°F | 46,000 Btu/h | 45,500 Btu/h |
| Heat at 17°F | 28,000 Btu/h | 30,000 Btu/h |
| Heat at 5°F | 21,000 Btu/h | N/A |
| COP at 5°F | 2 | N/A |