Carrier 26SCA4 vs. York YC6 for 2-ton central AC

Both deliver 24,000 Btu/h of cooling. The York adds a second stage, and its rating includes a particular furnace.

What does the second stage buy?

The Carrier runs at a single compressor stage and rates 15.2 SEER2. The two-stage York rates 17 SEER2. For an illustrative 24 million Btu of cooling over a season, those ratings imply about 1,579 kWh for the Carrier and 1,412 kWh for the York. Multiply the 167 kWh difference by your electricity rate to put a value on that part of the upgrade.

A lower running stage can also mean longer cooling cycles on mild days. If humidity is the complaint, ask what airflow the installer will set on low stage and how they will check it.

Find the furnace model on the York quote

The York rating includes the CTM30B5ACS1 indoor coil and TM9V080B12MP12 furnace. The Carrier record lists the F55AA*B30L* indoor unit. If the plan is to keep an existing furnace, get a rating for the exact combination that will be in the house. Include any necessary indoor work when comparing the two installed prices.

Specifications side by side

Figures apply to the equipment combinations shown. N/A marks a field that is missing or does not apply. These ratings come from the EPA’s final central AC archive. Check the exact match and availability with your installer.

SpecificationCarrier 26SCA424N**30*York YC624E2S11
System typeSplit central air conditionerSplit central air conditioner
Outdoor / packaged model26SCA424N**30*YC624E2S11
Indoor modelF55AA*B30L*CTM30B5ACS1
Furnace in this ratingN/ATM9V080B12MP12
AHRI reference216453835216600367
EPA product ID38501543898801
Compressor stagingSingle-stageTwo-stage
RefrigerantR-454BR-454B
Cooling capacity24,000 Btu/h24,000 Btu/h
SEER215.217
EER212.512.75