HVAC MatchupQuote worksheet

Rated equipment configuration

Trane 5WCZ5030A1 · rating 216574934

The published rating for this configuration lists 29,600 Btu/h of cooling.

Equipment on the rating

System type
Packaged heat pump
Outdoor / packaged model
5WCZ5030A1
Indoor model
N/A
Furnace in this rating
N/A
AHRI reference
216574934
EPA product ID
4518342
Compressor staging
Two-stage
Refrigerant
R-454B
Cooling capacity
29,600 Btu/h
SEER2
15.2
EER2
11.2
HSPF2
7.2
Heat at 47°F
28,800 Btu/h
Heat at 17°F
17,300 Btu/h
Heat at 5°F
14,700 Btu/h
COP at 5°F
2

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 65.8 kWh.

At the published 5°F test point, the system delivers 14,700 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 51% of its listed 47°F heating output (14,700 versus 28,800 Btu/h).

Check the cabinet dimensions, duct openings and connection details against the equipment it will replace.

Seasonal cooling electricity65.8kWh per million Btu0/100Score 0 / 100
Peak cooling power1.07kW per ton at the EER2 test point73/100Score 73 / 100
Seasonal heating electricity138.9kWh per million Btu0/100Score 0 / 100
Heating electricity at 5°F146.5kWh per million Btu at 5°F89/100Score 89 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.