Rated equipment configuration

Trane 5TWX7048A1 · rating 216764425

The published rating for this configuration lists 43,500 Btu/h of cooling. Check the indoor model 5PX*C009AS3 against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
5TWX7048A1
Indoor model
5PX*C009AS3
Furnace in this rating
S8X1C080M5PSC
AHRI reference
216764425
EPA product ID
3980557
Compressor staging
Two-stage
Refrigerant
R-454B
Cooling capacity
43,500 Btu/h
SEER2
16.5
EER2
12
HSPF2
9
Heat at 47°F
44,000 Btu/h
Heat at 17°F
29,200 Btu/h
Heat at 5°F
32,200 Btu/h
COP at 5°F
2.2

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 60.6 kWh.

At the published 5°F test point, the system delivers 32,200 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 73% of its listed 47°F heating output (32,200 versus 44,000 Btu/h).

The rating includes furnace S8X1C080M5PSC. Ask for the rating of the new combination if the proposal keeps another furnace.

Seasonal cooling electricity60.6kWh per million Btu29/100Score 29 / 100
Peak cooling power1.00kW per ton at the EER2 test point83/100Score 83 / 100
Seasonal heating electricity111.1kWh per million Btu55/100Score 55 / 100
Heating electricity at 5°F133.2kWh per million Btu at 5°F76/100Score 76 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.