HVAC MatchupQuote worksheet

Rated equipment configuration

Trane 5TWR7036A1 · rating 216763636

The published rating for this configuration lists 32,600 Btu/h of cooling. Check the indoor model 5PX*BD04AS3 against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
5TWR7036A1
Indoor model
5PX*BD04AS3
Furnace in this rating
S8X1B060M4PSC
AHRI reference
216763636
EPA product ID
3979545
Compressor staging
Two-stage
Refrigerant
R-454B
Cooling capacity
32,600 Btu/h
SEER2
17.1
EER2
11.7
HSPF2
8.2
Heat at 47°F
33,400 Btu/h
Heat at 17°F
21,600 Btu/h
Heat at 5°F
24,400 Btu/h
COP at 5°F
1.9

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 58.5 kWh.

At the published 5°F test point, the system delivers 24,400 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 73% of its listed 47°F heating output (24,400 versus 33,400 Btu/h).

The rating includes furnace S8X1B060M4PSC. Ask for the rating of the new combination if the proposal keeps another furnace.

Seasonal cooling electricity58.5kWh per million Btu40/100Score 40 / 100
Peak cooling power1.03kW per ton at the EER2 test point78/100Score 78 / 100
Seasonal heating electricity122.0kWh per million Btu20/100Score 20 / 100
Heating electricity at 5°F154.2kWh per million Btu at 5°F29/100Score 29 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.