HVAC MatchupQuote worksheet

Rated equipment configuration

Trane 5TWR6024A1 · rating 218106732

The published rating for this configuration lists 24,800 Btu/h of cooling. Check the indoor model 5TXCC009AS3+TSTAT against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
5TWR6024A1
Indoor model
5TXCC009AS3+TSTAT
Furnace in this rating
*UHMC100CCV4
AHRI reference
218106732
EPA product ID
4573815
Compressor staging
Single-stage
Refrigerant
R-454B
Cooling capacity
24,800 Btu/h
SEER2
16.5
EER2
12
HSPF2
8
Heat at 47°F
21,400 Btu/h
Heat at 17°F
14,500 Btu/h
Heat at 5°F
11,200 Btu/h
COP at 5°F
2.21

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 60.6 kWh.

At the published 5°F test point, the system delivers 11,200 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 52% of its listed 47°F heating output (11,200 versus 21,400 Btu/h).

The rating includes furnace *UHMC100CCV4. Ask for the rating of the new combination if the proposal keeps another furnace.

Seasonal cooling electricity60.6kWh per million Btu29/100Score 29 / 100
Peak cooling power1.00kW per ton at the EER2 test point83/100Score 83 / 100
Seasonal heating electricity125.0kWh per million Btu10/100Score 10 / 100
Heating electricity at 5°F132.6kWh per million Btu at 5°F77/100Score 77 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.