Rated equipment configuration

Trane 5TWR5030A1 · rating 214078349

The published rating for this configuration lists 27,800 Btu/h of cooling. Check the indoor model 5TEM6D04AV31+TDR+TSTAT against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
5TWR5030A1
Indoor model
5TEM6D04AV31+TDR+TSTAT
Furnace in this rating
N/A
AHRI reference
214078349
EPA product ID
3423687
Compressor staging
Single-stage
Refrigerant
R-454B
Cooling capacity
27,800 Btu/h
SEER2
15.2
EER2
12
HSPF2
8.1
Heat at 47°F
26,000 Btu/h
Heat at 17°F
17,400 Btu/h
Heat at 5°F
13,500 Btu/h
COP at 5°F
2.2

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 65.8 kWh.

At the published 5°F test point, the system delivers 13,500 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 52% of its listed 47°F heating output (13,500 versus 26,000 Btu/h).

Seasonal cooling electricity65.8kWh per million Btu0/100Score 0 / 100
Peak cooling power1.00kW per ton at the EER2 test point83/100Score 83 / 100
Seasonal heating electricity123.5kWh per million Btu15/100Score 15 / 100
Heating electricity at 5°F133.2kWh per million Btu at 5°F76/100Score 76 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.