HVAC MatchupQuote worksheet

Rated equipment configuration

Trane 5HPL5048A1000AA · rating 216374488

The published rating for this configuration lists 46,000 Btu/h of cooling. Check the indoor model 5TEM6D06AV41+TDR against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
5HPL5048A1000AA
Indoor model
5TEM6D06AV41+TDR
Furnace in this rating
N/A
AHRI reference
216374488
EPA product ID
3813836
Compressor staging
Two-stage
Refrigerant
R-454B
Cooling capacity
46,000 Btu/h
SEER2
16
EER2
11.7
HSPF2
8.1
Heat at 47°F
48,000 Btu/h
Heat at 17°F
42,000 Btu/h
Heat at 5°F
38,000 Btu/h
COP at 5°F
1.75

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 62.5 kWh.

At the published 5°F test point, the system delivers 38,000 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 79% of its listed 47°F heating output (38,000 versus 48,000 Btu/h).

Seasonal cooling electricity62.5kWh per million Btu18/100Score 18 / 100
Peak cooling power1.03kW per ton at the EER2 test point78/100Score 78 / 100
Seasonal heating electricity123.5kWh per million Btu15/100Score 15 / 100
Heating electricity at 5°F167.5kWh per million Btu at 5°F0/100Score 0 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.