HVAC MatchupQuote worksheet

Rated equipment configuration

Tempstar N5A8T24*K*WAA* · rating 215954910

The published rating for this configuration lists 24,000 Btu/h of cooling. Check the indoor model EVD5X36M17A* against your proposal.

Equipment on the rating

System type
Split central air conditioner
Outdoor / packaged model
N5A8T24*K*WAA*
Indoor model
EVD5X36M17A*
Furnace in this rating
OMV112K14A
AHRI reference
215954910
EPA product ID
3730701
Compressor staging
Two-stage
Refrigerant
R-454B
Cooling capacity
24,000 Btu/h
SEER2
17
EER2
13
HSPF2
N/A
Heat at 47°F
N/A
Heat at 17°F
N/A
Heat at 5°F
N/A
COP at 5°F
N/A

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 58.8 kWh.

The cooling rating gives no gas heating efficiency. If the bid includes a furnace, get its separate AFUE and rated heat output.

The rating includes furnace OMV112K14A. Ask for the rating of the new combination if the proposal keeps another furnace.

Seasonal cooling electricity58.8kWh per million Btu34/100Score 34 / 100
Peak cooling power0.92kW per ton at the EER2 test point43/100Score 43 / 100
Seasonal heating electricityN/AkWh per million BtuScore N/A
Heating electricity at 5°FN/AkWh per million Btu at 5°FScore N/A

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

EPA archived this central AC product list when the specification ended in February 2026. Verify the quoted combination and availability with the supplier.