HVAC MatchupQuote worksheet

Rated equipment configuration

Ruud RA15AY48AJ1N · rating 215828058

The published rating for this configuration lists 45,500 Btu/h of cooling. Check the indoor model RH2VY6024STACN against your proposal.

Equipment on the rating

System type
Split central air conditioner
Outdoor / packaged model
RA15AY48AJ1N
Indoor model
RH2VY6024STACN
Furnace in this rating
N/A
AHRI reference
215828058
EPA product ID
3707212
Compressor staging
Single-stage
Refrigerant
R-454B
Cooling capacity
45,500 Btu/h
SEER2
15.2
EER2
12
HSPF2
N/A
Heat at 47°F
N/A
Heat at 17°F
N/A
Heat at 5°F
N/A
COP at 5°F
N/A

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 65.8 kWh.

The cooling rating gives no gas heating efficiency. If the bid includes a furnace, get its separate AFUE and rated heat output.

The listed indoor model is RH2VY6024STACN. Substituting a different coil can change the cooling rating.

Seasonal cooling electricity65.8kWh per million Btu0/100Score 0 / 100
Peak cooling power1.00kW per ton at the EER2 test point0/100Score 0 / 100
Seasonal heating electricityN/AkWh per million BtuScore N/A
Heating electricity at 5°FN/AkWh per million Btu at 5°FScore N/A

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

EPA archived this central AC product list when the specification ended in February 2026. Verify the quoted combination and availability with the supplier.