Rated equipment configuration
Rheem RD16AY36AJVC · rating 218719577
The published rating for this configuration lists 34,200 Btu/h of cooling. Check the indoor model RCFY3624MTANM against your proposal.
Equipment on the rating
- System type
- Split heat pump
- Outdoor / packaged model
- RD16AY36AJVC
- Indoor model
- RCFY3624MTANM
- Furnace in this rating
- R972V1155A24UPS
- AHRI reference
- 218719577
- EPA product ID
- 4704377
- Compressor staging
- Variable-speed
- Refrigerant
- R-454B
- Cooling capacity
- 34,200 Btu/h
- SEER2
- 17
- EER2
- 11
- HSPF2
- 8.5
- Heat at 47°F
- 33,200 Btu/h
- Heat at 17°F
- 23,400 Btu/h
- Heat at 5°F
- 19,200 Btu/h
- COP at 5°F
- 2.4
What the numbers mean
For each million Btu of seasonal cooling, the published SEER2 works out to 58.8 kWh.
At the published 5°F test point, the system delivers 19,200 Btu/h. Compare that with the heating load at the same temperature.
At 5°F the unit delivers 58% of its listed 47°F heating output (19,200 versus 33,200 Btu/h).
The rating includes furnace R972V1155A24UPS. Ask for the rating of the new combination if the proposal keeps another furnace.
Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.
Source record
Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.