HVAC MatchupQuote worksheet

Rated equipment configuration

Rheem RD16AY36AJVC · rating 218719577

The published rating for this configuration lists 34,200 Btu/h of cooling. Check the indoor model RCFY3624MTANM against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
RD16AY36AJVC
Indoor model
RCFY3624MTANM
Furnace in this rating
R972V1155A24UPS
AHRI reference
218719577
EPA product ID
4704377
Compressor staging
Variable-speed
Refrigerant
R-454B
Cooling capacity
34,200 Btu/h
SEER2
17
EER2
11
HSPF2
8.5
Heat at 47°F
33,200 Btu/h
Heat at 17°F
23,400 Btu/h
Heat at 5°F
19,200 Btu/h
COP at 5°F
2.4

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 58.8 kWh.

At the published 5°F test point, the system delivers 19,200 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 58% of its listed 47°F heating output (19,200 versus 33,200 Btu/h).

The rating includes furnace R972V1155A24UPS. Ask for the rating of the new combination if the proposal keeps another furnace.

Seasonal cooling electricity58.8kWh per million Btu38/100Score 38 / 100
Peak cooling power1.09kW per ton at the EER2 test point65/100Score 65 / 100
Seasonal heating electricity117.6kWh per million Btu34/100Score 34 / 100
Heating electricity at 5°F122.1kWh per million Btu at 5°F100/100Score 100 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.