HVAC MatchupQuote worksheet

Gas furnace model

Lennox SLP99UH135XV60DK gas furnace

Lennox SLP99UH135XV60DK furnace specifications, including 98.4% AFUE, fuel input and delivered heating output.

Heating specifications

Furnace model
SLP99UH135XV60DK
Fuel
Natural gas
Burner
Modulating
AFUE
98.4%
Rated gas input
132,000 Btu/h
Rated heat output
128,000 Btu/h
Low-fire input
46,000 Btu/h
Low-fire heat output
45,000 Btu/h

Use these figures on a quote

Compare the 128,000 Btu/h rated heating output with the winter heat loss on your load calculation. The input rating measures the fuel entering the furnace.

At the published AFUE, delivering one million Btu of seasonal heat requires about 10.16 therms of gas. Multiply by your gas rate per therm to estimate the fuel cost for that amount of heat.

Seasonal gas use10.16therms per million Btu of heat97/100Score 97 / 100 across catalog furnaces