HVAC MatchupQuote worksheet

Gas furnace model

Lennox SLP99UH090XV36CK gas furnace

Lennox SLP99UH090XV36CK furnace specifications, including 98.1% AFUE, fuel input and delivered heating output.

Heating specifications

Furnace model
SLP99UH090XV36CK
Fuel
Natural gas
Burner
Modulating
AFUE
98.1%
Rated gas input
88,000 Btu/h
Rated heat output
86,000 Btu/h
Low-fire input
31,000 Btu/h
Low-fire heat output
30,000 Btu/h

Use these figures on a quote

Compare the 86,000 Btu/h rated heating output with the winter heat loss on your load calculation. The input rating measures the fuel entering the furnace.

At the published AFUE, delivering one million Btu of seasonal heat requires about 10.19 therms of gas. Multiply by your gas rate per therm to estimate the fuel cost for that amount of heat.

Seasonal gas use10.19therms per million Btu of heat96/100Score 96 / 100 across catalog furnaces

Source documents