HVAC MatchupQuote worksheet

Rated equipment configuration

Lennox ML16KP2-060-230A** · rating 218457521

The published rating for this configuration lists 58,500 Btu/h of cooling. Check the indoor model CBK47UHET-060-230-** against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
ML16KP2-060-230A**
Indoor model
CBK47UHET-060-230-**
Furnace in this rating
N/A
AHRI reference
218457521
EPA product ID
4617465
Compressor staging
Two-stage
Refrigerant
R-454B
Cooling capacity
58,500 Btu/h
SEER2
15.8
EER2
12.2
HSPF2
7.8
Heat at 47°F
54,500 Btu/h
Heat at 17°F
34,200 Btu/h
Heat at 5°F
27,800 Btu/h
COP at 5°F
2.1

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 63.3 kWh.

At the published 5°F test point, the system delivers 27,800 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 51% of its listed 47°F heating output (27,800 versus 54,500 Btu/h).

Seasonal cooling electricity63.3kWh per million Btu14/100Score 14 / 100
Peak cooling power0.98kW per ton at the EER2 test point86/100Score 86 / 100
Seasonal heating electricity128.2kWh per million Btu0/100Score 0 / 100
Heating electricity at 5°F139.6kWh per million Btu at 5°F62/100Score 62 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.