HVAC MatchupQuote worksheet

Rated equipment configuration

Lennox LRP15HPK24VP-* · rating 216799802

The published rating for this configuration lists 23,000 Btu/h of cooling.

Equipment on the rating

System type
Packaged heat pump
Outdoor / packaged model
LRP15HPK24VP-*
Indoor model
N/A
Furnace in this rating
N/A
AHRI reference
216799802
EPA product ID
3995471
Compressor staging
Two-stage
Refrigerant
R-454B
Cooling capacity
23,000 Btu/h
SEER2
16
EER2
12
HSPF2
7.2
Heat at 47°F
21,400 Btu/h
Heat at 17°F
12,200 Btu/h
Heat at 5°F
8,300 Btu/h
COP at 5°F
1.6

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 62.5 kWh.

At the published 5°F test point, the system delivers 8,300 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 39% of its listed 47°F heating output (8,300 versus 21,400 Btu/h).

Check the cabinet dimensions, duct openings and connection details against the equipment it will replace.

Seasonal cooling electricity62.5kWh per million Btu25/100Score 25 / 100
Peak cooling power1.00kW per ton at the EER2 test point93/100Score 93 / 100
Seasonal heating electricity138.9kWh per million Btu0/100Score 0 / 100
Heating electricity at 5°F183.2kWh per million Btu at 5°F32/100Score 32 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.