HVAC MatchupQuote worksheet

Gas furnace model

Lennox EL297UH110XE60CK gas furnace

Lennox EL297UH110XE60CK furnace specifications, including 97% AFUE, fuel input and delivered heating output.

Heating specifications

Furnace model
EL297UH110XE60CK
Fuel
Natural gas
Burner
Two-stage
AFUE
97%
Rated gas input
110,000 Btu/h
Rated heat output
108,000 Btu/h
Low-fire input
72,000 Btu/h
Low-fire heat output
71,000 Btu/h

Use these figures on a quote

Compare the 108,000 Btu/h rated heating output with the winter heat loss on your load calculation. The input rating measures the fuel entering the furnace.

At the published AFUE, delivering one million Btu of seasonal heat requires about 10.31 therms of gas. Multiply by your gas rate per therm to estimate the fuel cost for that amount of heat.

Seasonal gas use10.31therms per million Btu of heat91/100Score 91 / 100 across catalog furnaces