Rated equipment configuration

Lennox EL21KLV-060-230A** · rating 217117003

The published rating for this configuration lists 54,500 Btu/h of cooling. Check the indoor model CK40[C,U]T-49C-**+TDR against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
EL21KLV-060-230A**
Indoor model
CK40[C,U]T-49C-**+TDR
Furnace in this rating
SL280UH080NV60C*
AHRI reference
217117003
EPA product ID
4006024
Compressor staging
Variable-speed
Refrigerant
R-454B
Cooling capacity
54,500 Btu/h
SEER2
20.5
EER2
11.7
HSPF2
8.5
Heat at 47°F
54,000 Btu/h
Heat at 17°F
45,500 Btu/h
Heat at 5°F
35,600 Btu/h
COP at 5°F
2.12

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 48.8 kWh.

At the published 5°F test point, the system delivers 35,600 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 66% of its listed 47°F heating output (35,600 versus 54,000 Btu/h).

The rating includes furnace SL280UH080NV60C*. Ask for the rating of the new combination if the proposal keeps another furnace.

Seasonal cooling electricity48.8kWh per million Btu94/100Score 94 / 100
Peak cooling power1.03kW per ton at the EER2 test point78/100Score 78 / 100
Seasonal heating electricity117.6kWh per million Btu34/100Score 34 / 100
Heating electricity at 5°F138.2kWh per million Btu at 5°F64/100Score 64 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.