Rated equipment configuration
Lennox EL19KPV-024-230A** · rating 217194132
The published rating for this configuration lists 24,000 Btu/h of cooling. Check the indoor model CK40[C,U]T-36B-**+TDR against your proposal.
Equipment on the rating
- System type
- Split heat pump
- Outdoor / packaged model
- EL19KPV-024-230A**
- Indoor model
- CK40[C,U]T-36B-**+TDR
- Furnace in this rating
- EL195UH040NE36B*
- AHRI reference
- 217194132
- EPA product ID
- 4011058
- Compressor staging
- Variable-speed
- Refrigerant
- R-454B
- Cooling capacity
- 24,000 Btu/h
- SEER2
- 18
- EER2
- 12.6
- HSPF2
- 8.5
- Heat at 47°F
- 23,200 Btu/h
- Heat at 17°F
- 15,800 Btu/h
- Heat at 5°F
- 15,500 Btu/h
- COP at 5°F
- 1.88
What the numbers mean
For each million Btu of seasonal cooling, the published SEER2 works out to 55.6 kWh.
At the published 5°F test point, the system delivers 15,500 Btu/h. Compare that with the heating load at the same temperature.
At 5°F the unit delivers 67% of its listed 47°F heating output (15,500 versus 23,200 Btu/h).
The rating includes furnace EL195UH040NE36B*. Ask for the rating of the new combination if the proposal keeps another furnace.
Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.
Source record
Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.