Rated equipment configuration
Lennox EL16KP1-042-230A** · rating 215740176
The published rating for this configuration lists 41,500 Btu/h of cooling. Check the indoor model CK40[C,U]T-48C-**+TDR against your proposal.
Equipment on the rating
- System type
- Split heat pump
- Outdoor / packaged model
- EL16KP1-042-230A**
- Indoor model
- CK40[C,U]T-48C-**+TDR
- Furnace in this rating
- ML180UH110V60C*
- AHRI reference
- 215740176
- EPA product ID
- 3652328
- Compressor staging
- Single-stage
- Refrigerant
- R-454B
- Cooling capacity
- 41,500 Btu/h
- SEER2
- 15.5
- EER2
- 13
- HSPF2
- 7.8
- Heat at 47°F
- 39,500 Btu/h
- Heat at 17°F
- 24,800 Btu/h
- Heat at 5°F
- 20,400 Btu/h
- COP at 5°F
- 2.12
What the numbers mean
For each million Btu of seasonal cooling, the published SEER2 works out to 64.5 kWh.
At the published 5°F test point, the system delivers 20,400 Btu/h. Compare that with the heating load at the same temperature.
At 5°F the unit delivers 52% of its listed 47°F heating output (20,400 versus 39,500 Btu/h).
The rating includes furnace ML180UH110V60C*. Ask for the rating of the new combination if the proposal keeps another furnace.
Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.
Source record
Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.