HVAC MatchupQuote worksheet

Rated equipment configuration

Lennox EL16KP1-042-230A** · rating 215740176

The published rating for this configuration lists 41,500 Btu/h of cooling. Check the indoor model CK40[C,U]T-48C-**+TDR against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
EL16KP1-042-230A**
Indoor model
CK40[C,U]T-48C-**+TDR
Furnace in this rating
ML180UH110V60C*
AHRI reference
215740176
EPA product ID
3652328
Compressor staging
Single-stage
Refrigerant
R-454B
Cooling capacity
41,500 Btu/h
SEER2
15.5
EER2
13
HSPF2
7.8
Heat at 47°F
39,500 Btu/h
Heat at 17°F
24,800 Btu/h
Heat at 5°F
20,400 Btu/h
COP at 5°F
2.12

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 64.5 kWh.

At the published 5°F test point, the system delivers 20,400 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 52% of its listed 47°F heating output (20,400 versus 39,500 Btu/h).

The rating includes furnace ML180UH110V60C*. Ask for the rating of the new combination if the proposal keeps another furnace.

Seasonal cooling electricity64.5kWh per million Btu7/100Score 7 / 100
Peak cooling power0.92kW per ton at the EER2 test point97/100Score 97 / 100
Seasonal heating electricity128.2kWh per million Btu0/100Score 0 / 100
Heating electricity at 5°F138.2kWh per million Btu at 5°F64/100Score 64 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.