HVAC MatchupQuote worksheet

Rated equipment configuration

Innovair TPV60H2XA · rating 218338176

The published rating for this configuration lists 56,000 Btu/h of cooling.

Equipment on the rating

System type
Packaged heat pump
Outdoor / packaged model
TPV60H2XA
Indoor model
N/A
Furnace in this rating
N/A
AHRI reference
218338176
EPA product ID
4591056
Compressor staging
Variable-speed
Refrigerant
R-32
Cooling capacity
56,000 Btu/h
SEER2
17
EER2
10
HSPF2
8.8
Heat at 47°F
56,000 Btu/h
Heat at 17°F
34,200 Btu/h
Heat at 5°F
40,000 Btu/h
COP at 5°F
2

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 58.8 kWh.

At the published 5°F test point, the system delivers 40,000 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 71% of its listed 47°F heating output (40,000 versus 56,000 Btu/h).

Check the cabinet dimensions, duct openings and connection details against the equipment it will replace.

Seasonal cooling electricity58.8kWh per million Btu53/100Score 53 / 100
Peak cooling power1.20kW per ton at the EER2 test point37/100Score 37 / 100
Seasonal heating electricity113.6kWh per million Btu75/100Score 75 / 100
Heating electricity at 5°F146.5kWh per million Btu at 5°F89/100Score 89 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.