HVAC MatchupQuote worksheet

Rated equipment configuration

Heil N5A8T60*K*WAA* · rating 215983513

The published rating for this configuration lists 58,000 Btu/h of cooling. Check the indoor model FTMA5B60L0D* against your proposal.

Equipment on the rating

System type
Split central air conditioner
Outdoor / packaged model
N5A8T60*K*WAA*
Indoor model
FTMA5B60L0D*
Furnace in this rating
N/A
AHRI reference
215983513
EPA product ID
3763114
Compressor staging
Two-stage
Refrigerant
R-454B
Cooling capacity
58,000 Btu/h
SEER2
16.5
EER2
12
HSPF2
N/A
Heat at 47°F
N/A
Heat at 17°F
N/A
Heat at 5°F
N/A
COP at 5°F
N/A

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 60.6 kWh.

The cooling rating gives no gas heating efficiency. If the bid includes a furnace, get its separate AFUE and rated heat output.

The listed indoor model is FTMA5B60L0D*. Substituting a different coil can change the cooling rating.

Seasonal cooling electricity60.6kWh per million Btu25/100Score 25 / 100
Peak cooling power1.00kW per ton at the EER2 test point0/100Score 0 / 100
Seasonal heating electricityN/AkWh per million BtuScore N/A
Heating electricity at 5°FN/AkWh per million Btu at 5°FScore N/A

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

EPA archived this central AC product list when the specification ended in February 2026. Verify the quoted combination and availability with the supplier.