Rated equipment configuration
GREE GK-H05TC/NHA-D(U) · rating 215866831
The published rating for this configuration lists 56,000 Btu/h of cooling.
Equipment on the rating
- System type
- Packaged heat pump
- Outdoor / packaged model
- GK-H05TC/NHA-D(U)
- Indoor model
- N/A
- Furnace in this rating
- N/A
- AHRI reference
- 215866831
- EPA product ID
- 3721889
- Compressor staging
- Variable-speed
- Refrigerant
- R-32
- Cooling capacity
- 56,000 Btu/h
- SEER2
- 18
- EER2
- 11.2
- HSPF2
- 8.3
- Heat at 47°F
- 57,000 Btu/h
- Heat at 17°F
- 34,000 Btu/h
- Heat at 5°F
- 51,000 Btu/h
- COP at 5°F
- 2
What the numbers mean
For each million Btu of seasonal cooling, the published SEER2 works out to 55.6 kWh.
At the published 5°F test point, the system delivers 51,000 Btu/h. Compare that with the heating load at the same temperature.
At 5°F the unit delivers 89% of its listed 47°F heating output (51,000 versus 57,000 Btu/h).
Check the cabinet dimensions, duct openings and connection details against the equipment it will replace.
Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.
Source record
Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.