Rated equipment configuration

Goodman GLZS5BA3010A* · rating 215381161

The published rating for this configuration lists 28,600 Btu/h of cooling. Check the indoor model AMST30BU1300A* against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
GLZS5BA3010A*
Indoor model
AMST30BU1300A*
Furnace in this rating
N/A
AHRI reference
215381161
EPA product ID
3984042
Compressor staging
Single-stage
Refrigerant
R-32
Cooling capacity
28,600 Btu/h
SEER2
15.2
EER2
12.5
HSPF2
7.8
Heat at 47°F
28,600 Btu/h
Heat at 17°F
17,400 Btu/h
Heat at 5°F
13,600 Btu/h
COP at 5°F
1.95

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 65.8 kWh.

At the published 5°F test point, the system delivers 13,600 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 48% of its listed 47°F heating output (13,600 versus 28,600 Btu/h).

Seasonal cooling electricity65.8kWh per million Btu0/100Score 0 / 100
Peak cooling power0.96kW per ton at the EER2 test point90/100Score 90 / 100
Seasonal heating electricity128.2kWh per million Btu0/100Score 0 / 100
Heating electricity at 5°F150.3kWh per million Btu at 5°F38/100Score 38 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.