Rated equipment configuration
GE NS21H60MA5-**A · rating 217642437
The published rating for this configuration lists 54,500 Btu/h of cooling. Check the indoor model NCU[C,U]49CT5*-**+TDR against your proposal.
Equipment on the rating
- System type
- Split heat pump
- Outdoor / packaged model
- NS21H60MA5-**A
- Indoor model
- NCU[C,U]49CT5*-**+TDR
- Furnace in this rating
- NF80X100V5C*
- AHRI reference
- 217642437
- EPA product ID
- 4481594
- Compressor staging
- Variable-speed
- Refrigerant
- R-454B
- Cooling capacity
- 54,500 Btu/h
- SEER2
- 20.5
- EER2
- 11.7
- HSPF2
- 8.5
- Heat at 47°F
- 54,000 Btu/h
- Heat at 17°F
- 45,500 Btu/h
- Heat at 5°F
- 35,600 Btu/h
- COP at 5°F
- 2.12
What the numbers mean
For each million Btu of seasonal cooling, the published SEER2 works out to 48.8 kWh.
At the published 5°F test point, the system delivers 35,600 Btu/h. Compare that with the heating load at the same temperature.
At 5°F the unit delivers 66% of its listed 47°F heating output (35,600 versus 54,000 Btu/h).
The rating includes furnace NF80X100V5C*. Ask for the rating of the new combination if the proposal keeps another furnace.
Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.
Source record
Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.