HVAC MatchupQuote worksheet

Rated equipment configuration

GE NS21H36MA5-**A · rating 217642641

The published rating for this configuration lists 32,400 Btu/h of cooling. Check the indoor model NCU[C,U]30BT5*-**+TDR against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
NS21H36MA5-**A
Indoor model
NCU[C,U]30BT5*-**+TDR
Furnace in this rating
NF95X040S3B*
AHRI reference
217642641
EPA product ID
4481526
Compressor staging
Variable-speed
Refrigerant
R-454B
Cooling capacity
32,400 Btu/h
SEER2
18
EER2
11.2
HSPF2
10.2
Heat at 47°F
33,200 Btu/h
Heat at 17°F
27,000 Btu/h
Heat at 5°F
22,600 Btu/h
COP at 5°F
2.24

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 55.6 kWh.

At the published 5°F test point, the system delivers 22,600 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 68% of its listed 47°F heating output (22,600 versus 33,200 Btu/h).

The rating includes furnace NF95X040S3B*. Ask for the rating of the new combination if the proposal keeps another furnace.

Seasonal cooling electricity55.6kWh per million Btu56/100Score 56 / 100
Peak cooling power1.07kW per ton at the EER2 test point69/100Score 69 / 100
Seasonal heating electricity98.0kWh per million Btu97/100Score 97 / 100
Heating electricity at 5°F130.8kWh per million Btu at 5°F81/100Score 81 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record