HVAC MatchupQuote worksheet

Rated equipment configuration

Fujitsu FOP1936MJAYCA · rating 215611120

The published rating for this configuration lists 34,200 Btu/h of cooling. Check the indoor model FHRAVM3621M*YECA against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
FOP1936MJAYCA
Indoor model
FHRAVM3621M*YECA
Furnace in this rating
N/A
AHRI reference
215611120
EPA product ID
3630409
Compressor staging
Variable-speed
Refrigerant
R-454B
Cooling capacity
34,200 Btu/h
SEER2
20
EER2
12.5
HSPF2
9.5
Heat at 47°F
34,200 Btu/h
Heat at 17°F
30,000 Btu/h
Heat at 5°F
29,400 Btu/h
COP at 5°F
2.1

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 50.0 kWh.

At the published 5°F test point, the system delivers 29,400 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 86% of its listed 47°F heating output (29,400 versus 34,200 Btu/h).

Seasonal cooling electricity50.0kWh per million Btu87/100Score 87 / 100
Peak cooling power0.96kW per ton at the EER2 test point90/100Score 90 / 100
Seasonal heating electricity105.3kWh per million Btu74/100Score 74 / 100
Heating electricity at 5°F139.6kWh per million Btu at 5°F62/100Score 62 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.