HVAC MatchupQuote worksheet

Rated equipment configuration

Daikin DH9VSA6010A* · rating 217989105

The published rating for this configuration lists 54,000 Btu/h of cooling. Check the indoor model DFVE60DP1300A* against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
DH9VSA6010A*
Indoor model
DFVE60DP1300A*
Furnace in this rating
N/A
AHRI reference
217989105
EPA product ID
4518351
Compressor staging
Variable-speed
Refrigerant
R-32
Cooling capacity
54,000 Btu/h
SEER2
18
EER2
10.5
HSPF2
9
Heat at 47°F
54,000 Btu/h
Heat at 17°F
33,400 Btu/h
Heat at 5°F
47,000 Btu/h
COP at 5°F
1.9

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 55.6 kWh.

At the published 5°F test point, the system delivers 47,000 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 87% of its listed 47°F heating output (47,000 versus 54,000 Btu/h).

Seasonal cooling electricity55.6kWh per million Btu56/100Score 56 / 100
Peak cooling power1.14kW per ton at the EER2 test point55/100Score 55 / 100
Seasonal heating electricity111.1kWh per million Btu55/100Score 55 / 100
Heating electricity at 5°F154.2kWh per million Btu at 5°F29/100Score 29 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.