Rated equipment configuration
Daikin DH9VSA6010A* · rating 217989105
The published rating for this configuration lists 54,000 Btu/h of cooling. Check the indoor model DFVE60DP1300A* against your proposal.
Equipment on the rating
- System type
- Split heat pump
- Outdoor / packaged model
- DH9VSA6010A*
- Indoor model
- DFVE60DP1300A*
- Furnace in this rating
- N/A
- AHRI reference
- 217989105
- EPA product ID
- 4518351
- Compressor staging
- Variable-speed
- Refrigerant
- R-32
- Cooling capacity
- 54,000 Btu/h
- SEER2
- 18
- EER2
- 10.5
- HSPF2
- 9
- Heat at 47°F
- 54,000 Btu/h
- Heat at 17°F
- 33,400 Btu/h
- Heat at 5°F
- 47,000 Btu/h
- COP at 5°F
- 1.9
What the numbers mean
For each million Btu of seasonal cooling, the published SEER2 works out to 55.6 kWh.
At the published 5°F test point, the system delivers 47,000 Btu/h. Compare that with the heating load at the same temperature.
At 5°F the unit delivers 87% of its listed 47°F heating output (47,000 versus 54,000 Btu/h).
Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.
Source record
Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.