Daikin DH9VSA4810A* · rating 217989107

The published rating for this configuration lists 46,000 Btu/h of cooling. Check the indoor model DFVE60DP1300A* against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
DH9VSA4810A*
Indoor model
DFVE60DP1300A*
Furnace in this rating
N/A
AHRI reference
217989107
EPA product ID
4518352
Compressor staging
Variable-speed
Refrigerant
R-32
Cooling capacity
46,000 Btu/h
SEER2
18
EER2
11.7
HSPF2
9
Heat at 47°F
48,000 Btu/h
Heat at 17°F
30,000 Btu/h
Heat at 5°F
44,000 Btu/h
COP at 5°F
1.9

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 55.6 kWh.

At the published 5°F test point, the system delivers 44,000 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 92% of its listed 47°F heating output (44,000 versus 48,000 Btu/h).

Seasonal cooling electricity55.6kWh per million Btu56/100Score 56 / 100
Peak cooling power1.03kW per ton at the EER2 test point78/100Score 78 / 100
Seasonal heating electricity111.1kWh per million Btu55/100Score 55 / 100
Heating electricity at 5°F154.2kWh per million Btu at 5°F29/100Score 29 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.