Rated equipment configuration
Carrier 37MUHAQ30AA3 · rating 215318750
The published rating for this configuration lists 30,000 Btu/h of cooling. Check the indoor model 45MUAAQ30XX3 against your proposal.
Equipment on the rating
- System type
- Split heat pump
- Outdoor / packaged model
- 37MUHAQ30AA3
- Indoor model
- 45MUAAQ30XX3
- Furnace in this rating
- N/A
- AHRI reference
- 215318750
- EPA product ID
- 3560591
- Compressor staging
- Variable-speed
- Refrigerant
- R-454B
- Cooling capacity
- 30,000 Btu/h
- SEER2
- 16.9
- EER2
- 11.7
- HSPF2
- 10
- Heat at 47°F
- 34,000 Btu/h
- Heat at 17°F
- 23,800 Btu/h
- Heat at 5°F
- 32,600 Btu/h
- COP at 5°F
- 1.96
What the numbers mean
For each million Btu of seasonal cooling, the published SEER2 works out to 59.2 kWh.
At the published 5°F test point, the system delivers 32,600 Btu/h. Compare that with the heating load at the same temperature.
At 5°F the unit delivers 96% of its listed 47°F heating output (32,600 versus 34,000 Btu/h).
Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.
Source record
Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.