HVAC MatchupQuote worksheet

Rated equipment configuration

Carrier 27VNA048A*030* · rating 215662627

The published rating for this configuration lists 45,500 Btu/h of cooling. Check the indoor model FE5BN(B,X)C48L*+UI against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
27VNA048A*030*
Indoor model
FE5BN(B,X)C48L*+UI
Furnace in this rating
N/A
AHRI reference
215662627
EPA product ID
3967080
Compressor staging
Variable-speed
Refrigerant
R-454B
Cooling capacity
45,500 Btu/h
SEER2
18.5
EER2
10.5
HSPF2
9.5
Heat at 47°F
48,000 Btu/h
Heat at 17°F
42,000 Btu/h
Heat at 5°F
33,600 Btu/h
COP at 5°F
2.14

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 54.1 kWh.

At the published 5°F test point, the system delivers 33,600 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 70% of its listed 47°F heating output (33,600 versus 48,000 Btu/h).

Seasonal cooling electricity54.1kWh per million Btu65/100Score 65 / 100
Peak cooling power1.14kW per ton at the EER2 test point55/100Score 55 / 100
Seasonal heating electricity105.3kWh per million Btu74/100Score 74 / 100
Heating electricity at 5°F136.9kWh per million Btu at 5°F67/100Score 67 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.