HVAC MatchupQuote worksheet

Rated equipment configuration

Carrier 27TPA836A**30* · rating 215638458

The published rating for this configuration lists 35,800 Btu/h of cooling. Check the indoor model CAA**4321AM* against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
27TPA836A**30*
Indoor model
CAA**4321AM*
Furnace in this rating
59TN6C080C21**20
AHRI reference
215638458
EPA product ID
3719669
Compressor staging
Two-stage
Refrigerant
R-454B
Cooling capacity
35,800 Btu/h
SEER2
15.5
EER2
12
HSPF2
8
Heat at 47°F
38,500 Btu/h
Heat at 17°F
23,800 Btu/h
Heat at 5°F
19,300 Btu/h
COP at 5°F
2.26

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 64.5 kWh.

At the published 5°F test point, the system delivers 19,300 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 50% of its listed 47°F heating output (19,300 versus 38,500 Btu/h).

The rating includes furnace 59TN6C080C21**20. Ask for the rating of the new combination if the proposal keeps another furnace.

Seasonal cooling electricity64.5kWh per million Btu7/100Score 7 / 100
Peak cooling power1.00kW per ton at the EER2 test point83/100Score 83 / 100
Seasonal heating electricity125.0kWh per million Btu10/100Score 10 / 100
Heating electricity at 5°F129.7kWh per million Btu at 5°F83/100Score 83 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.