HVAC MatchupQuote worksheet

Rated equipment configuration

Bryant PH5SAN536**AA* · rating 214141631

The published rating for this configuration lists 33,800 Btu/h of cooling. Check the indoor model CAA**4821AM* against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
PH5SAN536**AA*
Indoor model
CAA**4821AM*
Furnace in this rating
83*SB48060M17***
AHRI reference
214141631
EPA product ID
3400337
Compressor staging
Single-stage
Refrigerant
R-454B
Cooling capacity
33,800 Btu/h
SEER2
15.2
EER2
12
HSPF2
7.8
Heat at 47°F
33,200 Btu/h
Heat at 17°F
22,400 Btu/h
Heat at 5°F
17,600 Btu/h
COP at 5°F
2.18

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 65.8 kWh.

At the published 5°F test point, the system delivers 17,600 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 53% of its listed 47°F heating output (17,600 versus 33,200 Btu/h).

The rating includes furnace 83*SB48060M17***. Ask for the rating of the new combination if the proposal keeps another furnace.

Seasonal cooling electricity65.8kWh per million Btu0/100Score 0 / 100
Peak cooling power1.00kW per ton at the EER2 test point83/100Score 83 / 100
Seasonal heating electricity128.2kWh per million Btu0/100Score 0 / 100
Heating electricity at 5°F134.4kWh per million Btu at 5°F73/100Score 73 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record