HVAC MatchupQuote worksheet

Rated equipment configuration

Bryant 575ENWB36****A* · rating 217489134

The published rating for this configuration lists 34,200 Btu/h of cooling.

Equipment on the rating

System type
Packaged central air conditioner
Outdoor / packaged model
575ENWB36****A*
Indoor model
N/A
Furnace in this rating
N/A
AHRI reference
217489134
EPA product ID
4464061
Compressor staging
Two-stage
Refrigerant
R-454B
Cooling capacity
34,200 Btu/h
SEER2
15.2
EER2
11.5
HSPF2
N/A
Heat at 47°F
N/A
Heat at 17°F
N/A
Heat at 5°F
N/A
COP at 5°F
N/A

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 65.8 kWh.

The cooling rating gives no gas heating efficiency. If the bid includes a furnace, get its separate AFUE and rated heat output.

Check the cabinet dimensions, duct openings and connection details against the equipment it will replace.

Seasonal cooling electricity65.8kWh per million Btu0/100Score 0 / 100
Peak cooling power1.04kW per ton at the EER2 test point81/100Score 81 / 100
Seasonal heating electricityN/AkWh per million BtuScore N/A
Heating electricity at 5°FN/AkWh per million Btu at 5°FScore N/A

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

EPA archived this central AC product list when the specification ended in February 2026. Verify the quoted combination and availability with the supplier.