HVAC MatchupQuote worksheet

Rated equipment configuration

Bryant 293VAN036**AA* · rating 215932035

The published rating for this configuration lists 32,200 Btu/h of cooling. Check the indoor model CAA**3617AM*+UI against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
293VAN036**AA*
Indoor model
CAA**3617AM*+UI
Furnace in this rating
83*CA36040C17***
AHRI reference
215932035
EPA product ID
3724431
Compressor staging
Variable-speed
Refrigerant
R-454B
Cooling capacity
32,200 Btu/h
SEER2
19.5
EER2
11
HSPF2
9.5
Heat at 47°F
N/A
Heat at 17°F
31,000 Btu/h
Heat at 5°F
27,200 Btu/h
COP at 5°F
1.98

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 51.3 kWh.

At the published 5°F test point, the system delivers 27,200 Btu/h. Compare that with the heating load at the same temperature.

The rating includes furnace 83*CA36040C17***. Ask for the rating of the new combination if the proposal keeps another furnace.

Seasonal cooling electricity51.3kWh per million Btu80/100Score 80 / 100
Peak cooling power1.09kW per ton at the EER2 test point65/100Score 65 / 100
Seasonal heating electricity105.3kWh per million Btu74/100Score 74 / 100
Heating electricity at 5°F148.0kWh per million Btu at 5°F43/100Score 43 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.