Rated equipment configuration
Bryant 249VAN060**AA* · rating 217918609
The published rating for this configuration lists 54,500 Btu/h of cooling. Check the indoor model CVAMA6021XMA* against your proposal.
Equipment on the rating
- System type
- Split heat pump
- Outdoor / packaged model
- 249VAN060**AA*
- Indoor model
- CVAMA6021XMA*
- Furnace in this rating
- 82*TB60090V21***
- AHRI reference
- 217918609
- EPA product ID
- 4536304
- Compressor staging
- Variable-speed
- Refrigerant
- R-454B
- Cooling capacity
- 54,500 Btu/h
- SEER2
- 15.5
- EER2
- 11
- HSPF2
- 8
- Heat at 47°F
- 59,500 Btu/h
- Heat at 17°F
- 49,500 Btu/h
- Heat at 5°F
- 39,500 Btu/h
- COP at 5°F
- 1.94
What the numbers mean
For each million Btu of seasonal cooling, the published SEER2 works out to 64.5 kWh.
At the published 5°F test point, the system delivers 39,500 Btu/h. Compare that with the heating load at the same temperature.
At 5°F the unit delivers 66% of its listed 47°F heating output (39,500 versus 59,500 Btu/h).
The rating includes furnace 82*TB60090V21***. Ask for the rating of the new combination if the proposal keeps another furnace.
Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.
Source record
Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.