HVAC MatchupQuote worksheet

Rated equipment configuration

Bryant 249VAN060**AA* · rating 217918609

The published rating for this configuration lists 54,500 Btu/h of cooling. Check the indoor model CVAMA6021XMA* against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
249VAN060**AA*
Indoor model
CVAMA6021XMA*
Furnace in this rating
82*TB60090V21***
AHRI reference
217918609
EPA product ID
4536304
Compressor staging
Variable-speed
Refrigerant
R-454B
Cooling capacity
54,500 Btu/h
SEER2
15.5
EER2
11
HSPF2
8
Heat at 47°F
59,500 Btu/h
Heat at 17°F
49,500 Btu/h
Heat at 5°F
39,500 Btu/h
COP at 5°F
1.94

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 64.5 kWh.

At the published 5°F test point, the system delivers 39,500 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 66% of its listed 47°F heating output (39,500 versus 59,500 Btu/h).

The rating includes furnace 82*TB60090V21***. Ask for the rating of the new combination if the proposal keeps another furnace.

Seasonal cooling electricity64.5kWh per million Btu7/100Score 7 / 100
Peak cooling power1.09kW per ton at the EER2 test point65/100Score 65 / 100
Seasonal heating electricity125.0kWh per million Btu10/100Score 10 / 100
Heating electricity at 5°F151.1kWh per million Btu at 5°F36/100Score 36 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.