HVAC MatchupQuote worksheet

Rated equipment configuration

Bryant 248TAN048**AA* · rating 216464286

The published rating for this configuration lists 47,500 Btu/h of cooling. Check the indoor model F55AA*C48L* against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
248TAN048**AA*
Indoor model
F55AA*C48L*
Furnace in this rating
N/A
AHRI reference
216464286
EPA product ID
3847199
Compressor staging
Two-stage
Refrigerant
R-454B
Cooling capacity
47,500 Btu/h
SEER2
16
EER2
12.5
HSPF2
8.1
Heat at 47°F
48,500 Btu/h
Heat at 17°F
30,400 Btu/h
Heat at 5°F
24,600 Btu/h
COP at 5°F
2.28

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 62.5 kWh.

At the published 5°F test point, the system delivers 24,600 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 51% of its listed 47°F heating output (24,600 versus 48,500 Btu/h).

Seasonal cooling electricity62.5kWh per million Btu18/100Score 18 / 100
Peak cooling power0.96kW per ton at the EER2 test point90/100Score 90 / 100
Seasonal heating electricity123.5kWh per million Btu15/100Score 15 / 100
Heating electricity at 5°F128.5kWh per million Btu at 5°F86/100Score 86 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.