HVAC MatchupQuote worksheet

Rated equipment configuration

Bryant 235SAN060**AA* · rating 214601966

The published rating for this configuration lists 57,000 Btu/h of cooling. Check the indoor model FT5ANBD60L* against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
235SAN060**AA*
Indoor model
FT5ANBD60L*
Furnace in this rating
N/A
AHRI reference
214601966
EPA product ID
3438978
Compressor staging
Single-stage
Refrigerant
R-454B
Cooling capacity
57,000 Btu/h
SEER2
15.2
EER2
12.5
HSPF2
7.8
Heat at 47°F
55,500 Btu/h
Heat at 17°F
35,600 Btu/h
Heat at 5°F
28,600 Btu/h
COP at 5°F
2.18

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 65.8 kWh.

At the published 5°F test point, the system delivers 28,600 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 52% of its listed 47°F heating output (28,600 versus 55,500 Btu/h).

Seasonal cooling electricity65.8kWh per million Btu0/100Score 0 / 100
Peak cooling power0.96kW per ton at the EER2 test point90/100Score 90 / 100
Seasonal heating electricity128.2kWh per million Btu0/100Score 0 / 100
Heating electricity at 5°F134.4kWh per million Btu at 5°F73/100Score 73 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.