Rated equipment configuration

Bosch BPHA-60RCB-M16S · rating 216020663

The published rating for this configuration lists 57,000 Btu/h of cooling.

Equipment on the rating

System type
Packaged heat pump
Outdoor / packaged model
BPHA-60RCB-M16S
Indoor model
N/A
Furnace in this rating
N/A
AHRI reference
216020663
EPA product ID
3740548
Compressor staging
Variable-speed
Refrigerant
R-454B
Cooling capacity
57,000 Btu/h
SEER2
16
EER2
9
HSPF2
8.5
Heat at 47°F
57,000 Btu/h
Heat at 17°F
40,500 Btu/h
Heat at 5°F
40,000 Btu/h
COP at 5°F
1.8

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 62.5 kWh.

At the published 5°F test point, the system delivers 40,000 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 70% of its listed 47°F heating output (40,000 versus 57,000 Btu/h).

Check the cabinet dimensions, duct openings and connection details against the equipment it will replace.

Seasonal cooling electricity62.5kWh per million Btu25/100Score 25 / 100
Peak cooling power1.33kW per ton at the EER2 test point0/100Score 0 / 100
Seasonal heating electricity117.6kWh per million Btu63/100Score 63 / 100
Heating electricity at 5°F162.8kWh per million Btu at 5°F64/100Score 64 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.