HVAC MatchupQuote worksheet

Rated equipment configuration

Bosch BOVB-60RTB-M15S · rating 217895261

The published rating for this configuration lists 43,000 Btu/h of cooling. Check the indoor model BMAC4248BBTA against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
BOVB-60RTB-M15S
Indoor model
BMAC4248BBTA
Furnace in this rating
BGH96M080B3C
AHRI reference
217895261
EPA product ID
4512087
Compressor staging
Variable-speed
Refrigerant
R-454B
Cooling capacity
43,000 Btu/h
SEER2
16
EER2
10.5
HSPF2
8.5
Heat at 47°F
44,000 Btu/h
Heat at 17°F
33,000 Btu/h
Heat at 5°F
31,000 Btu/h
COP at 5°F
1.85

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 62.5 kWh.

At the published 5°F test point, the system delivers 31,000 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 70% of its listed 47°F heating output (31,000 versus 44,000 Btu/h).

The rating includes furnace BGH96M080B3C. Ask for the rating of the new combination if the proposal keeps another furnace.

Seasonal cooling electricity62.5kWh per million Btu18/100Score 18 / 100
Peak cooling power1.14kW per ton at the EER2 test point55/100Score 55 / 100
Seasonal heating electricity117.6kWh per million Btu34/100Score 34 / 100
Heating electricity at 5°F158.4kWh per million Btu at 5°F20/100Score 20 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.