HVAC MatchupQuote worksheet

Rated equipment configuration

Armstrong Air A7AC14F59P-**A · rating 215594788

The published rating for this configuration lists 55,000 Btu/h of cooling. Check the indoor model 7EH51CX-**+TDR against your proposal.

Equipment on the rating

System type
Split central air conditioner
Outdoor / packaged model
A7AC14F59P-**A
Indoor model
7EH51CX-**+TDR
Furnace in this rating
A80UH1E090C20*
AHRI reference
215594788
EPA product ID
3636988
Compressor staging
Single-stage
Refrigerant
R-454B
Cooling capacity
55,000 Btu/h
SEER2
15.2
EER2
12.6
HSPF2
N/A
Heat at 47°F
N/A
Heat at 17°F
N/A
Heat at 5°F
N/A
COP at 5°F
N/A

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 65.8 kWh.

The cooling rating gives no gas heating efficiency. If the bid includes a furnace, get its separate AFUE and rated heat output.

The rating includes furnace A80UH1E090C20*. Ask for the rating of the new combination if the proposal keeps another furnace.

Seasonal cooling electricity65.8kWh per million Btu0/100Score 0 / 100
Peak cooling power0.95kW per ton at the EER2 test point27/100Score 27 / 100
Seasonal heating electricityN/AkWh per million BtuScore N/A
Heating electricity at 5°FN/AkWh per million Btu at 5°FScore N/A

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

EPA archived this central AC product list when the specification ended in February 2026. Verify the quoted combination and availability with the supplier.