HVAC MatchupQuote worksheet

Rated equipment configuration

American Standard 5A6V8X36A1 · rating 215864514

The published rating for this configuration lists 32,000 Btu/h of cooling. Check the indoor model 5PX*BD04AS3 against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
5A6V8X36A1
Indoor model
5PX*BD04AS3
Furnace in this rating
S8V2B060M4PCB
AHRI reference
215864514
EPA product ID
3715428
Compressor staging
Variable-speed
Refrigerant
R-454B
Cooling capacity
32,000 Btu/h
SEER2
18.1
EER2
10
HSPF2
8.5
Heat at 47°F
34,200 Btu/h
Heat at 17°F
32,000 Btu/h
Heat at 5°F
26,000 Btu/h
COP at 5°F
2

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 55.2 kWh.

At the published 5°F test point, the system delivers 26,000 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 76% of its listed 47°F heating output (26,000 versus 34,200 Btu/h).

The rating includes furnace S8V2B060M4PCB. Ask for the rating of the new combination if the proposal keeps another furnace.

Seasonal cooling electricity55.2kWh per million Btu58/100Score 58 / 100
Peak cooling power1.20kW per ton at the EER2 test point44/100Score 44 / 100
Seasonal heating electricity117.6kWh per million Btu34/100Score 34 / 100
Heating electricity at 5°F146.5kWh per million Btu at 5°F46/100Score 46 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.