HVAC MatchupQuote worksheet

Rated equipment configuration

American Standard 5A6V0X36A1 · rating 216439317

The published rating for this configuration lists 34,600 Btu/h of cooling. Check the indoor model 5TEMCD04AV31+TDR against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
5A6V0X36A1
Indoor model
5TEMCD04AV31+TDR
Furnace in this rating
N/A
AHRI reference
216439317
EPA product ID
3846039
Compressor staging
Variable-speed
Refrigerant
R-454B
Cooling capacity
34,600 Btu/h
SEER2
19.2
EER2
12
HSPF2
9.4
Heat at 47°F
32,800 Btu/h
Heat at 17°F
31,000 Btu/h
Heat at 5°F
25,400 Btu/h
COP at 5°F
2.24

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 52.1 kWh.

At the published 5°F test point, the system delivers 25,400 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 77% of its listed 47°F heating output (25,400 versus 32,800 Btu/h).

Seasonal cooling electricity52.1kWh per million Btu75/100Score 75 / 100
Peak cooling power1.00kW per ton at the EER2 test point83/100Score 83 / 100
Seasonal heating electricity106.4kWh per million Btu70/100Score 70 / 100
Heating electricity at 5°F130.8kWh per million Btu at 5°F81/100Score 81 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.