Rated equipment configuration
American Standard 5A6H7048A1 · rating 216763924
The published rating for this configuration lists 43,500 Btu/h of cooling. Check the indoor model 5PX*C009AS3 against your proposal.
Equipment on the rating
- System type
- Split heat pump
- Outdoor / packaged model
- 5A6H7048A1
- Indoor model
- 5PX*C009AS3
- Furnace in this rating
- L8V1C100U5VSB
- AHRI reference
- 216763924
- EPA product ID
- 3979825
- Compressor staging
- Two-stage
- Refrigerant
- R-454B
- Cooling capacity
- 43,500 Btu/h
- SEER2
- 17.1
- EER2
- 12
- HSPF2
- 9
- Heat at 47°F
- 43,500 Btu/h
- Heat at 17°F
- 29,000 Btu/h
- Heat at 5°F
- 32,000 Btu/h
- COP at 5°F
- 2.2
What the numbers mean
For each million Btu of seasonal cooling, the published SEER2 works out to 58.5 kWh.
At the published 5°F test point, the system delivers 32,000 Btu/h. Compare that with the heating load at the same temperature.
At 5°F the unit delivers 74% of its listed 47°F heating output (32,000 versus 43,500 Btu/h).
The rating includes furnace L8V1C100U5VSB. Ask for the rating of the new combination if the proposal keeps another furnace.
Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.
Source record
Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.