HVAC MatchupQuote worksheet

Rated equipment configuration

American Standard 5A6H7024A1 · rating 216763531

The published rating for this configuration lists 24,000 Btu/h of cooling. Check the indoor model 5TXCB006AS3 against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
5A6H7024A1
Indoor model
5TXCB006AS3
Furnace in this rating
*UHMB080CCV3
AHRI reference
216763531
EPA product ID
3979667
Compressor staging
Two-stage
Refrigerant
R-454B
Cooling capacity
24,000 Btu/h
SEER2
17.1
EER2
12.5
HSPF2
9.4
Heat at 47°F
21,800 Btu/h
Heat at 17°F
15,400 Btu/h
Heat at 5°F
17,300 Btu/h
COP at 5°F
2

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 58.5 kWh.

At the published 5°F test point, the system delivers 17,300 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 79% of its listed 47°F heating output (17,300 versus 21,800 Btu/h).

The rating includes furnace *UHMB080CCV3. Ask for the rating of the new combination if the proposal keeps another furnace.

Seasonal cooling electricity58.5kWh per million Btu40/100Score 40 / 100
Peak cooling power0.96kW per ton at the EER2 test point90/100Score 90 / 100
Seasonal heating electricity106.4kWh per million Btu70/100Score 70 / 100
Heating electricity at 5°F146.5kWh per million Btu at 5°F46/100Score 46 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.