HVAC MatchupQuote worksheet

Rated equipment configuration

American Standard 5A6H5042A1 · rating 214078976

The published rating for this configuration lists 41,000 Btu/h of cooling. Check the indoor model 5TXCD010AS3+TSTAT against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
5A6H5042A1
Indoor model
5TXCD010AS3+TSTAT
Furnace in this rating
S8V2D120M5PCB
AHRI reference
214078976
EPA product ID
3423539
Compressor staging
Single-stage
Refrigerant
R-454B
Cooling capacity
41,000 Btu/h
SEER2
16
EER2
12
HSPF2
8.1
Heat at 47°F
39,500 Btu/h
Heat at 17°F
25,200 Btu/h
Heat at 5°F
19,100 Btu/h
COP at 5°F
2.2

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 62.5 kWh.

At the published 5°F test point, the system delivers 19,100 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 48% of its listed 47°F heating output (19,100 versus 39,500 Btu/h).

The rating includes furnace S8V2D120M5PCB. Ask for the rating of the new combination if the proposal keeps another furnace.

Seasonal cooling electricity62.5kWh per million Btu18/100Score 18 / 100
Peak cooling power1.00kW per ton at the EER2 test point83/100Score 83 / 100
Seasonal heating electricity123.5kWh per million Btu15/100Score 15 / 100
Heating electricity at 5°F133.2kWh per million Btu at 5°F76/100Score 76 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record