Rated equipment configuration
American Standard 5A5V0X36A1 · rating 218792276
The published rating for this configuration lists 26,200 Btu/h of cooling. Check the indoor model 5TEMCD04AV31+TDR against your proposal.
Equipment on the rating
- System type
- Split heat pump
- Outdoor / packaged model
- 5A5V0X36A1
- Indoor model
- 5TEMCD04AV31+TDR
- Furnace in this rating
- N/A
- AHRI reference
- 218792276
- EPA product ID
- 4704981
- Compressor staging
- Variable-speed
- Refrigerant
- R-454B
- Cooling capacity
- 26,200 Btu/h
- SEER2
- 20
- EER2
- 12.3
- HSPF2
- 10.3
- Heat at 47°F
- 33,200 Btu/h
- Heat at 17°F
- 34,200 Btu/h
- Heat at 5°F
- 35,600 Btu/h
- COP at 5°F
- 2.27
What the numbers mean
For each million Btu of seasonal cooling, the published SEER2 works out to 50.0 kWh.
At the published 5°F test point, the system delivers 35,600 Btu/h. Compare that with the heating load at the same temperature.
At 5°F the unit delivers 107% of its listed 47°F heating output (35,600 versus 33,200 Btu/h).
Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.
Source record
Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.