HVAC MatchupQuote worksheet

Rated equipment configuration

Amana AZV9SA361CA* · rating 216699865

The published rating for this configuration lists 34,200 Btu/h of cooling. Check the indoor model AHVE60DP1300A* against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
AZV9SA361CA*
Indoor model
AHVE60DP1300A*
Furnace in this rating
N/A
AHRI reference
216699865
EPA product ID
3894035
Compressor staging
Variable-speed
Refrigerant
R-32
Cooling capacity
34,200 Btu/h
SEER2
19
EER2
11.7
HSPF2
9.2
Heat at 47°F
33,800 Btu/h
Heat at 17°F
32,000 Btu/h
Heat at 5°F
33,000 Btu/h
COP at 5°F
2.1

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 52.6 kWh.

At the published 5°F test point, the system delivers 33,000 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 98% of its listed 47°F heating output (33,000 versus 33,800 Btu/h).

Seasonal cooling electricity52.6kWh per million Btu72/100Score 72 / 100
Peak cooling power1.03kW per ton at the EER2 test point78/100Score 78 / 100
Seasonal heating electricity108.7kWh per million Btu63/100Score 63 / 100
Heating electricity at 5°F139.6kWh per million Btu at 5°F62/100Score 62 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.